E: 58.↓. Intake Grille Error (Indoor Unit) - Fujitsu ASUH18LMAS Service Manual

Wall mounted type
Hide thumbs Also See for ASUH18LMAS:
Table of Contents

Advertisement

2-14. E: 58.X. Intake grille error (Indoor unit)
Indoor unit
Indicator
Outdoor unit
Indoor unit main PCB
Detective actuator
Micro switch
Forecast of cause
Check point 1. Check limit switch
Check operation of Micro switch. (any blocking by dust, etc.)
Remove Micro switch and check ON/OFF switching operation by using a meter.
-> If micro switch is detective, replace it.
Check point 2. Check connector (CN11)/wire
Check loose contact of CN11/shorted wire (pinched wire).
-> Replace micro switch if the wire is abnormal
Check point 3. Replace main PCB
If Check Point 1 and 2 do not improve the symptom, change main PCB.
2-14. E: 58.↓. Intake grille error (Indoor unit)
Operation indicator
Timer indicator
Economy indicator
Error code
Refer to
→hen the Micro switch is detected open while running
the compressor.
End
- (03-29) -
5 time flash
8 time flash
Continuous flash
E: 58
"Error code table (Outdoor unit)"
Micro switch failure
Shorted connector/wire
Main PCB failure
on page 03-4
2. Troubleshooting with error code

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asuh24lmasAouh18lmas1Aouh24lmas1

Table of Contents