2-14. E: 58.X. Intake grille error (Indoor unit)
Indoor unit
Indicator
Outdoor unit
Indoor unit main PCB
Detective actuator
Micro switch
Forecast of cause
Check point 1. Check limit switch
•
Check operation of Micro switch. (any blocking by dust, etc.)
•
Remove Micro switch and check ON/OFF switching operation by using a meter.
-> If micro switch is detective, replace it.
Check point 2. Check connector (CN11)/wire
Check loose contact of CN11/shorted wire (pinched wire).
-> Replace micro switch if the wire is abnormal
Check point 3. Replace main PCB
If Check Point 1 and 2 do not improve the symptom, change main PCB.
2-14. E: 58.↓. Intake grille error (Indoor unit)
Operation indicator
Timer indicator
Economy indicator
Error code
Refer to
→hen the Micro switch is detected open while running
the compressor.
End
- (03-29) -
5 time flash
8 time flash
Continuous flash
E: 58
"Error code table (Outdoor unit)"
Micro switch failure
Shorted connector/wire
Main PCB failure
on page 03-4