Adjusting the Upper Shaft Timing
Bottom dead point
Setscrew
(lowest position)
shield plate
1. Remove the spool stand and right cover (see pages
2. Open the factory adjusting menu window and press
3. Turn the handwheel clockwise.
4. Turn the handwheel clockwise.
NOTE:
The shield plates should not interfere with the sensors.
5. Attach the parts removed in step 1.
C point (needle
change) shield
plate
60
4 and 6).
the Phase key to open the Phase Sensor adjusting
window.
The indication next to Bottom dead pt. should
change from "L" to "H" when the index disk is set at
0º (L).
To adjust the bottom dead point (lowest position of the
needle) timing, loosen the setscrew on the lowest
position shield plate and turn it clockwise until the
indication changes from "L" to "H". Tighten the set
screw.
The indication next to Needle Change should
change from "L" to "H" when the index disk is set at
270º.
To adjust the needle change position timing, loosen
the setscrew on the C point (needle change) shield
plate and turn it clockwise until the indication changes
from "L" to "H".
Tighten the setscrew.