Replacing The Lateral Moving Unit - Janome MB-7e Service Manual And Parts List

V2
Table of Contents

Advertisement

Drive cover
Hole in the needle plate

Replacing the Lateral Moving Unit

Setscrew A
Setscrew B
Connector
Connector
Needle
To remove:
1. Remove the spool stand, right cover and left cover
(see pages 4 and 5).
2. Remove the thread tension panel (see page 4).
3. Remove the setscrews A (3 pcs.) and remove the
driver cover.
4. Disconnect the connectors.
5. Remove the setscrews B (2 pcs.) and remove the
lateral moving unit.
To attach:
6. Attach the lateral moving unit and partially fix it with the
setscrews B (2 pcs.).
7. Push the needle bar down and rotate the handwheel
to set the index disk at "L".
8. Adjust the position of the lateral moving unit so the
needle enters into the center of the hole in the needle
plate. Tighten the set screws B (2 pcs.) securely.
9. Connect the connectors and attach the parts removed
in steps 1 to 3.
40