Siemens SIMATIC NET SCALANCE W1788 Series Operating Instructions Manual page 32

Hide thumbs Also See for SIMATIC NET SCALANCE W1788 Series:
Table of Contents

Advertisement

Description of the device
4.5 LED display
LED
F
P1
P2
R1
32
Color
Meaning
Flashing green and
Data transfer via the WLAN interface 1.
yellow
Access point mode:
Flashing yellow
With DFS (802.11h), the channel is scanned for one minute for
competing radar signals before the channel can be used for data
traffic.
Interval:
100 ms on / 100 ms
off
Off
No fault/error.
Red
The device is starting up or an error has occurred.
Flashing red
The bootloader waits in this state for a new firmware file that you
can download by TFTP.
Interval:
500 ms on / 500 ms
off
Flashing red
Firmware on PLUG:
The device is performing a firmware update or downgrade.
Interval:
2000 ms on /
200 ms off
Red
A competing radar signal was found on all enabled channels.
Simultaneous
R1 yellow flashing
Flashing green
The port LEDs flash for detection of device location.
The "LED flash" function is activated
Either with SINEC PNI
Or via the WBM page "Discovery and Set via DCP"
Operating Instructions, 03/2022, C79000-G8976-C484-05
SCALANCE W1788-x / W1748-1

Advertisement

Table of Contents
loading

Table of Contents