6. Assemble the burner in a reverse sequence.
Replace the gas type sticker near the gas supply ramp
with the one related to the new gas type.
Regulating the air flow for the burners
Owing to the different characteristics of the gas used,
flames may receive insufficient or excessive air flow. In
this case, regulate the air flow by following the steps
outlined below:
1 Loosen screw C in the burner.
2 Rotate the air shutter D to position N for methane or
natural gas or to position G for liquid gas, align the
moving indicator on the shutter to the fixed indicator
on the burner to obtain a regular flame.
Examples
• Flame with excess air flow; small and weak: rotate air
shutter D to reduce opening x (anti-clockwise).
• Normal flame: bluish colour.
• Flame with insufficient air; irregular with yellow tips:
rotate air shutter D to increase opening x (clockwise).
20
D
X
C
G
Make sure that the gas supply pressure of the
appliance obeys the recommended values.
If the supply gas pressure is changeable or
different from the necessary pressure, you must
fit an applicable pressure adjuster on the gas
supply pipe.
Minimum level adjustment of the oven
burner
1. Disconnect the appliance from the electricity.
2. Turn the knob for the gas control to the minimum
position and remove it.
3. Adjust the adjustment screw (A) with a thin- bladed
screwdriver.
Change of the type
of gas
From natural gas
to liquid gas.
From liquid gas
to natural gas
4. Attach the knob for the gas control.
5. Connect the appliance to the electricity.
Adjustment of the
adjustment screw
Fully tighten the
adjustment
screw in.
Release the adjustment
screw
approximately
1/3 of a turn.