Trane Optimus RTHD Installation, Operation And Maintenance Manual page 84

Water-cooled chillers
Table of Contents

Advertisement

Diagnostics
Table 27. Communication diagnostics (continued)
Diagnostic Name
Affects
Comm Loss: External Heat
Heat
Recovery Enable
Recovery
Comm Loss: External Heat
Heat
Recovery Water
Recovery
Temperature Setpoint Input
Comm Loss: External Hot
Chiller
Water Command
Comm Loss: External Ice
Ice
Building Command
Building
Comm Loss: Heat Recovery
Heat
Enter Water Temperature
Recovery
Comm Loss: Heat Recovery
Heat
Leaving Water Temperature
Recovery
Comm Loss: Heat Recovery
Heat
Tank Water Temperature
Recovery
Comm Loss: Heat Recovery
Heat
Water Flow Switch
Recovery
Comm Loss: Heat Recovery
Heat
Water Pump Relay
Recovery
Comm Loss: High Pressure
Chiller
Cutout Switch
Comm Loss: Hot Gas
Chiller
Bypass Valve
Comm Loss: Ice Building
Ice
Status Relay
Building
Comm Loss: Liquid Line
Chiller
Bypass Valve
Comm Loss: Oil Loss Level
Chiller
Sensor Input
Comm Loss: Oil Pressure
Chiller
Comm Loss: Oil Return Gas
Chiller
Pump Drain
Comm Loss: Oil Return Gas
Chiller
Pump Fill
Comm Loss: Oil Return
Chiller
Purge Valve
Comm Loss: Op Status
Chiller
Programmable Relays
84
Active
Modes
[Inactive
Severity Persistence
Modes]
Warning
Latch
All
Warning
Latch
All
Warning
Latching
All
Normal
Latch
All
Warning
Latch
All
Warning
Latch
All
Normal
Latch
All
Normal
Latch
All
Warning
Latch
All
Normal
Latch
All
Normal
Latch
All
Normal
Latch
All
Normal
Latch
All
Normal
Latch
All
Normal
Latch
All
Normal
Latch
All
Normal
Latch
All
Normal
Latch
All
Warning
Latch
All
Criteria
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period. Chiller shall revert to normal (non-ice
building) mode regardless of last state.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second period
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period. Chiller shall revert to normal (non-ice
building) mode regardless of last state.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second period
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second period
Continual loss of communication between the MP and
the Functional ID has occurred for a 30 second
period.
Reset
Level
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
Remote
RTHD-SVX01K-EN