Trane Optimus RTHD Installation, Operation And Maintenance Manual page 23

Water-cooled chillers
Table of Contents

Advertisement

Table 7.
Rigging dimensions (continued)
Unit
(a)
Configuration
Units
mm
D1G2G2
in
mm
D2D2E2
in
mm
D2F2F3
in
mm
D2G2G1
in
mm
D2G3G3
in
mm
D3D2E2
in
mm
D3F2F3
in
mm
D3G2G1
in
mm
E3D2E2
in
mm
E3F2F3
in
mm
E3G2G1
in
mm
(a) Designator corresponds to digits 6, 7, 14, 15, 21 and 22 of model number.
Important:
Rigging dimensions given in
given as a starting point reference. Lifting
cables should be adjusted as necessary for
even unit lift.
WARNING
Improper Unit Lift!
Failure to properly lift unit in a LEVEL position could
result in unit dropping and possibly crushing operator/
technician which could result in death or serious injury,
and equipment or property-only damage. Test lift unit
approximately 24 inches (61 cm) to verify proper center
of gravity lift point. To avoid dropping of unit,
reposition lifting point if unit is not level.
WARNING
Risk of Unit Tipping!
Failure to do so may result in death or serious injury
should a lifting cable fail. Connect an anti-rotation strap
between the lifting beam and compressor before lifting
unit.
RTHD-SVX01K-EN
A
B
3658
3353
144
132
3658
3353
120
108
3048
2743
144
132
3658
3353
144
132
3658
3353
144
132
3658
3353
120
108
3048
2743
144
132
3658
3353
144
132
3658
3353
120
108
3048
2743
144
132
3658
3353
144
132
3658
3353
Table 7
are
Dimension - in (mm)
C
D
1612
99
63.54
3.82
1614
97
59.96
7.4
1523
188
63.39
3.98
1610
101
63.46
3.9
1612
99
63.46
3.9
1612
99
60
7.4
1523
188
63.39
3.98
1610
101
63.46
3.9
1612
99
60
4.57
1525
116
63.46
1.14
1612
29
63.82
0.79
1621
20
WARNING
Shipping Mounts!
Do not use the threaded holes in the compressor to lift
or assist in lifting the unit. They are not intended for
that purpose and could create a dangerous situation.
Do not remove the wood mounts until the unit is in its
final location. Removal of wood shipping mounts prior
to unit final locating could result in death or serious
injury or equipment damage.
NOTICE
Equipment Damage!
Never use a forklift to move the unit. The skid is not
designed to support the unit at any one point and
using a forklift to move the equipment may cause unit
damage. Always position the lifting beam so that
cables do not contact the unit. Failure to do so may
result in unit damage.
Note: If absolutely necessary, the chiller can be pushed or
pulled across a smooth surface if it is bolted to
wood shipping mounts.
1. See
Table 5, p. 17
or
Table 6, p. 18
weights.
Note: Weights are typical for units with R-134a
charge.
Installation Mechanical
E
F
654
610
26.02
24
661
610
24.17
24
614
610
24.29
24
617
610
25.75
24
654
610
25.75
24
654
610
24.17
24
614
610
24.29
24
617
610
25.75
24
654
610
24.09
24
612
610
24.21
24
615
610
26
24
661
610
for unit shipping
23