10.2

Jog operation

Group
LED display
Function
F20
group 1
I/O group
I22
Set the desired jog frequency in F20.
Select the terminal among the Multi-function input terminal P1 thru P5 to use for this setting.
If P3 is set for Jog operation, set I22 to 4 {Jog}.
Jog frequency can be set within the range of F21 - [Max frequency] and F22 – [Start frequency].
Jog operation overrides all other operations except Dwell operation. Therefore, if Jog frequency
command is entered in the middle of Multi-Step, Up-Down or 3-wire operation, operation is executed at
Jog frequency.
Voltage
P3
Run
command
Parameter name
Jog frequency
[Multi-function
terminal P3 define]
Frequency
P3 (JOG)
Run
command(FX)
F12
Set
Min/Max
value
-
input
4
P1
FX : I20 = 0
P3
JOG : I22=4
CM