7. Function list

LED
Parameter
display
name
0.0
[Frequency
command]
ACC
[Accel time]
dEC
[Decel time]
Drv
[Drive mode]
(Run/Stop
mode)
Frq
[Frequency
mode]
St1
[Multi-Step
frequency 1]
St2
[Multi-Step
frequency 2]
St3
[Multi-Step
frequency 3]
Min/Max
range
0/400
This parameter sets the frequency that the
[Hz]
inverter is commanded to output.
During Stop: Frequency Command
During Run: Output Frequency
During Multi-step operation: Multi-step
frequency 0.
It cannot be set greater than F21- [Max
frequency].
0/6000
During Multi-Accel/Decel operation, this
[sec]
parameter serves as Accel/Decel time 0.
0/3
0
Run/Stop via Run/Stop key on the keypad
Run/Stop
1
via control
terminal
2
3
Operation via Communication Option
0/8
0
Digital
1
Analog
2
3
4
5
6
7
8
0/400
This parameter sets Multi-Step frequency 1
[Hz]
during Multi-step operation.
This parameter sets Multi-Step frequency 2
during Multi-step operation.
This parameter sets Multi-Step frequency 3
during Multi-step operation.
Description
FX : Motor forward run
RX : Motor reverse run
FX : Run/Stop enable
RX : Reverse rotation select
Setting via Keypad 1
Setting via Keypad 2
Setting via potentiometer on
the keypad(V0)
Setting via V1 terminal
Setting via I terminal
Setting via potentiometer on
the keypad + I terminal
Setting via V1 + I terminal
Setting via potentiometer on
the keypad + V1 terminal
Modbus-RTU Communication
7-1
7. Function list
Drive Group
Factory
Adjustable
defaults
during run
0.0
O
5.0
O
10.0
O
1
X
0
X
10.0
O
20.0
O
30.0
O
SV-iC5
Page
9-1
9-10
9-10
9-7
9-7
9-1
9-1
9-2
9-3
9-3
9-4
9-4
9-5
9-6
9-6
9-6