Each boat type has a different breaker panel configuration to energize the system's electrical circuit. Once the circuit is energized, complete the following
steps:
Energize SINS unit on your vessel by energizing the DGPS Circuit Breakers on
1
the vessel. A beep will sound and the unit will proceed automatically in its startup
performance test check.
Note: DGPS GP-37 must be turned on first BEFORE the Furuno NavNet is
turned on.
Press DGPS/Heading Sensor [POWER] key.
2
Note: A beep will sound and the unit will proceed automatically in its startup
performance test check.
Press the [POWER/BRILL] key to turn the unit on.
3
Note: The first time you turn on the power (or any time the power is applied after
a memory reset) you are asked if you want to start in the simulation mode which
provides simulated operation of the equipment. Push the [ENTER] knob to start
the simulation mode, or press the [CLEAR] key to start normal operation.
A beep sounds and the equipment proceeds in the sequence shown
Note:
below, displaying product information, startup test results, and the chart usage
disclaimer. The startup test will check the internal ROM, RAM, internal battery
and backup data functions for proper operation and display the results for each
as OK or NG (No Good). If NG appears, an appropriate message appears on the
screen. For any NG, try to press any key to go to the chart disclaimer screen,
and then perform the diagnostic test. The magnetron takes from 1-2 minutes and
30 seconds (depending or radar model) to warm up before the radar can be
operated. The time remaining to complete the warm up of the magnetron is
counted down and displayed at the center of the display screen. You may press
any key at the chart disclaimer screen to show the last-used display feature or
wait several seconds to let the equipment do it for you.
Press Fathometer RD-30 [POWER] key.
4
Note: A beep will sound and unit will proceed automatically in its startup
performance test check.