Communications Parameters - Omron H8GN Owner's Manual

Hide thumbs Also See for H8GN:
Table of Contents

Advertisement

CHAPTER 1
ABOUT COMMUNICATIONS METHODS
J
Communications
parameters
Parameter
Communications unit No.
Baud rate
Communications data length
Communications stop bit
Communications parity
F
Communications
parameter setup
1-4
The H8GNs communications specifications are set in the communications
setting level. These parameters are set on the H8GNs front panel.
The following table shows the communications parameters and their set
ting ranges.
Displayed
Setting Range
Characters
0 to 99
1.2 / 2.4 / 4.8 /
7 / 8 (bit)
1 / 2
None / even / odd
Before you carry out communications with the H8GN, set up communica
tions unit No., Communication rate and other parameters by carrying out
the following procedure.
(1) Hold down the
operation level" to the initial setting level."
(2) Press the
key for less than one second to move from the initial
setting level" to the communications setting level."
(3) Select the parameters as shown below by pressing the
(4) Use the
or
Communications unit No.
Baud rate
Communications data length
Communications stop bit
Communications parity
0,
to 99
1
9.6 (k bit/s)
1.2 / 2.4 / 4.8 /
/ 8 (bit)
7
1 /
2
/
Highlighted characters indicate defaults.
key for at least three seconds to move from the
keys to change the parameter set values.
H8GN
Set Value
(k bit/s)
9.6
/
key.

Advertisement

Table of Contents
loading

Table of Contents