10. Make MOD SEQUENCE settings

a. Set SEQ COMMON parameters
As preparation before creating the actual sequence data,
the SEQ COMMON parameters are used to specify things
such as the maximum number of steps in the sequence and
the playback method. Use the [+/YES] [–/NO] keys to set
the values.
1 Press the SELECT [11] key.
The LCD screen will show Page 18A: SEQ COMMON
"Last Step."
Specify the length (maximum number of steps) of the
sequence that you wish to record, in the range of 1–16.
18A SEQ COMMON
Last Step:
2 Press the CURSOR [®] key.
The LCD screen will show Page 18B: SEQ COMMON
"Seq Type."
Specify the direction in which the steps will play back.
18B SEQ COMMON
Seq Type:Forward
3 Press the CURSOR [®] key.
The LCD screen will show Page 18C: SEQ COMMON
"Run Mode."
Specify the loop setting for sequence playback.
18C SEQ COMMON
Run Mode:Loop
4 Press the CURSOR [®] key.
The LCD screen will show Page 18D: SEQ COMMON
"Key Sync."
Specify how the sequence will be reset when a note-on
occurs.
18D SEQ COMMON
Key Sync:Timbre
5 Press the CURSOR [®] key.
The LCD screen will show Page 18E: SEQ COMMON
"Resolution."
Specify the playback speed of the sequence relative to
the internal clock.
18E SEQ COMMON
Resolution: 1/48
b. Specify sequence data for each step
Here's how to select a program for which sequence is
turned on, and record sequence data for each step.
1 In Program Play mode, select a program for which
2 Press the [EDIT] key.
3 Press the SEQ EDIT/CH PARAM [SELECT] key to
16
4 Press the [+/YES] key to set "Knob" to Cutoff.
5 Press the MOD SEQUENCE [ON/OFF] key.
6 Press and hold a note on the keyboard.
7 While listening to the sound, use the sixteen knobs
sequence is turned on.
You will enter LCD Edit mode.
make the SEQ 1 LED light.
The LCD screen will show Page 19A: SEQ 1 "Knob."
For this example, we will assign FILTER "Cutoff" to
SEQ1.
19A SEQ 1
Knob:None
19A SEQ 1
Knob:Cutoff
If you wish to assign a parameter to SEQ 2 or SEQ 3, use
the [SELECT] key to select SEQ 2 or SEQ 3.
The [ON/OFF] key LED will light, and the sequence
will be turned on.
The program will sound, and the SELECT [1]–[16] keys
will light consecutively.
located beside the SEQ EDIT LED to specify the
sequence data for each step.
The sixteen knobs are normally used to edit program
sounds (EG or LFO etc.), but when the [SELECT] key
has selected a sequence, they are used to set and edit
sequence data.
The numbers shown below each knob correspond to the
sequence steps. Rotate the knob for the step you wish to
set.
When you rotate a knob, the LCD screen will show 19C:
SEQ 1 "Step Value."
19C SEQ 1
Step[01]:
Step Number
The value of each step is the amount of change relative
to the parameter value that is currently written or set.
Basic Guide
+10
Value
25

Advertisement