End Caps Disassembly - Samson EB 31a-23 Mounting And Operating Instructions

Quarter-turn actuator with adjustable hydraulic damping. version hcd dap / hcd srp
Table of Contents

Advertisement

9.3.4

End caps disassembly

Refer to Fig. 9-1, Fig. 9-2, Fig. 9-8, Fig. 9-9, Fig. 9-10 and
Fig. 9-11
Disassemble one end cap at a time.
WARNING
Risk of personal injury due to compressed springs!
End caps are under tension due to compressed springs.
Before starting any work on the actuator disconnect all pneu-
matic / hydraulic / electrical supplies from the actuator and
exhaust the pressure from the power module.
Make sure that the actuator is in the closed position (0°) be-
fore disassembling.
Make sure that the stop cap screws (02) have been correctly
removed as per section 9.3.3
NOTICE
Risk of components damage due to incorrect disassembly!
During disassembly the end caps can be damaged due to une-
ven force generated by compressed springs.
Observe the specified sequence shown in Fig. 9-5.
Remove the end caps as shown in Fig. 9-4 keeping a con-
stant distance (A = B) between the actuator body and the end
cap interface. Remove the end caps as shown in Fig. 9-4
keeping a constant distance (A = B) between the actuator
body and the end cap interface.
Fig. 9-8:
Remove cap screws
EB 31a-23_EN
Edition: November 2021
Specifi cations subject to change
Fig. 9-9:
Revove end cap
Spring return actuators
Release the springs compression by partially unscrewing
each end cap bolt (318) 1 turn at a time as per the sequence
shown in Fig. 9-8 for the number of turns indicated in Ta-
ble 9-5.
Table 9-5: Number of turns
Quarter-turn actuator
DAP HCD / SRP HCD
30
60
100
150
300
450
600
1200
2000
3000
4000
WARNING
Risk of personal injury due to compressed springs!
End caps are under tension when the springs are compressed.
If there is still force on the end cap (30/30R) after unscrewing the
cap screws (318) for the number of turns indicated in Table 9-5,
the spring cartridge may have been damaged or the pistons are
not completely closed:
stop the disassembly and contact PFEIFFER.
Unscrew and remove the plug (339), see Fig. 9-10.
Unscrew completely the end cap bolts (318) as per the se-
quence shown in the Fig. 9-8.
Remove the end caps (30).
Remove the spring cartridges (17).
Remove the o-rings (14) Fig. 9-11.
Service
Number of turns for
screws (318)
5 ... 7 Umdrehungen
6 ... 8 Umdrehungen
9-7