To find Fluid Outlet Pressure(psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Fluid Outlet Pressure
psi
cycles per minute
MPa, bar
18
21, 210
A
B
14, 140
C
7, 70
gpm
liters/minute
3.8
Technical Data
(Model 237284 Bulldog Pump)
Performance Charts
A
0.7 MPa, 7 bar (100 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
35
50
66
7.6
11.4
15.2
To find Pump Air Consumption(m /min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
Air Consumption
scfm
cycles per minute
m /min
18
7.00
5.60
4.20
2.80
1.40
gpm
liters/minute
3.8
35
50
66
A
B
C
7.6
11.4
15.2