2.6.6
Controller Resetting (Following
System Shutdown or Warning)
Use the following procedure to restart the generator set
after a system shutdown or to clear a warning lamp
condition. This procedure includes the resetting of the
optional remote annunciator.
Refer to Section 2.6.1, Emergency Stop, to reset the
generator set after an emergency stop.
1. Disconnect the generator set load using the line
circuit breaker or automatic transfer switch.
2. Correct the cause of the fault shutdown or warning.
See the Safety Precautions and Instructions
section of this manual before proceeding.
3. Reset the fault by pressing the OFF/RESET
button.
4. Start the generator set by pressing the generator
set OFF/RESET button and then press the RUN
button.
When equipped, the remote annunciator alarm
horn sounds. Press the ALARM SILENCE/LAMP
TEST button to stop the alarm horn. The alarm
silenced lamp turns on if the alarm is silenced.
5. Test operate the generator set to verify correction
of the shutdown cause by pressing the RUN
button.
6. Press the generator set OFF/RESET button to stop
the generator set.
7. Press the generator set AUTO button.
8. Silence the controller alarm horn by pressing the
ALARM SILENCE button.
9. Reconnect the generator set load via the line circuit
breaker or automatic transfer switch.
10. When equipped, the remote annunciator alarm
horn sounds. Press the ALARM SILENCE/LAMP
TEST button to stop the alarm horn. The alarm
silenced lamp turns on if the alarm is silenced.
58
Section 2 Operation

2.7 Menu Displays

Use the Menu Summary List and Figure 2-10 after
reading and understanding the features of the
pushbutton/rotary selector dial.
Digital Display.
The Menu Summary List and Figure 2-10 provide a
quick reference to the digital display data. Some digital
display data may not be identical to your display due to
generator set application differences. The closed bullet
items represent main level data and the open bullet
items are sub-level data. The Menu Summary List
indicates items that are user selectable. Use SiteTecht
software for changing programmable information.
See Section 1.5.3,