Printed Circuit Board; Circuit Check Procedure - Daewoo KOG-311M0P Service Manual

Table of Contents

Advertisement

PRINTED CIRCUIT BOARD

1. CIRCUIT CHECK PROCEDURE

1) Low Voltage Transformer (DMR-604FS) Check.
The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage: 220V
1
2
NOTE 1: Secondary side voltage of the low voltage transformer changes in proportion to
fluctuation of power source voltage.
NOTE 2: The allowable tolerance of the secondary voltage is within ±5% of norminal voltage.
2) Voltage Check
KEY CHECK POINT
NO.
CHECK POINT
1
IC1 PIN 6, 10, 11
2
IC1 PIN 1
3
IC1 PIN 22
4
IC1 PIN 8 or 9
5
DP1 PIN 1 & 25
CHECK METHOD
MEASURE POINT
NO.
Fig. 9
1
MP1
2
MP2
3
MP3
NOTE : Each measure point must be measured with GND points.
Frequency: 60Hz
10
8
7
6
–5VDC
–30VDC
0V
-5V
2.4 VAC (DISPLAY FILAMENT VOLTAGE)
WAVE FORM
DC –5V ± 0.25
DC –30V ± 1.0
DC –27V ± 1.0
Voltage
Terminal
6–7
8–10
REMARK
T
T: 250ns
REMEDY
Replace ZD2, EC1, EC2
Replace R21, ZD3
Replace R21, R22, EC5
41
LOAD
NO LOAD
24V
30V
2.4V
2.5V
REMARK
NO LOAD
NO LOAD
NO LOAD

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kog-311q0p

Table of Contents