E) Measure the leakage by using microwave energy survery meter with dual ranges, set to 2,450 MHz.
– Measured radiation leakage must not exceed the values prescribed below.
• Leakage for a fully assembled oven with door normally closed must be less than 4mW/cm
– When measuring the leakage, always use the
5cm space cone with probe. Hold the probe
perpendicular to the cabinet, door. Place the
space cone of the probe on the door, cabinet,
door seam, along the seam, the door viewing
window, the exhaust air vents, the suction air
vents.
– Measuring should be in a counter-clockwise
direction at a rate of 1 inch/sec. If the leakage
of the cabinet door seam is unknow, move the
probe more slowly.
– When measuring near a corner of the door,
keep the probe perpendicular to the areas
making sure the probe end at the base of the
cone does not get closer than 2 inches from
any metal. If it does, erroneous reading may
result.

WIRING DIAGRAM

RD
POWER SUPPLY:
SINGLE PHASE~ONLY
BR(BK)
BL(WH)
GE(GN)
NOTE : RD : RED
WH : WHITE
BK : BLACK
GN : GREEN
BR : BROWN
INTERLOCK
PRIMARY
SWITCH
RD
RD
RD
RD
INTERLOCK
MONITOR
RD
RD
SWITCH
CONTROL P.W.B.ASS'Y
BL
RELAY-1
1
RELAY-2
BK
3
RELAY-4
GN
BL
SECONDARY
SWITCH
(D.O.M. SWITCH)
OR : ORANGE
CL : CAVITY LAMP
BL : BLUE
FM : FAN(BLOWER) MOTOR
GY : GRAY
GM : GEARED MOTOR
GE : GREEN/YELLOW
RD
L
R
5
GY
CL
BL
BL
GY
GRILL
THERMOSTAT
WH
[CONDITION]
DOOR : CLOSED
COOK : OFF
(Fig. 2)
19
HIGH VOLTAGE
TRANSFORMER
BL
GY
GY
GM
FM
GY
GY
WH
2
.
OR
H.V.
CAPACITOR
MAGNETRON
H.V. DIODE

Advertisement