Assembly And Installation; Preparing For Fitting And Installation - Vaillant aroTHERM VWL Series Installation Instructions Manual

Hide thumbs Also See for aroTHERM VWL Series:
Table of Contents

Advertisement

Visit www.centralheating.co.uk for more information.
Planning consent and Building works notification should be
submitted either to Building Control or to a Competent Per-
son Provider.
5

Assembly and installation

5.1

Preparing for fitting and installation

5.1.1
Delivery, transport and positioning
5.1.1.1 Transporting the product
Warning.
Risk of injury from lifting a heavy weight.
Lifting weights that are too heavy may cause
injury to the spine, for example.
When transporting the product, two
people should lift it.
Observe the product weight stated in the
technical data.
When transporting heavy loads, observe
the applicable directives and regulations.
Caution.
Risk of material damage due to incorrect
transportation.
Regardless of the mode of transport, the heat
pump must never be tilted by more than 45°.
Otherwise, this may lead to malfunctions
in the refrigerant circuit during subsequent
operation. In the worst case scenario, this
may lead to a fault in the whole system.
During transport, do not tilt the heat pump
by any more than the maximum angle of
45°.
Use the transportation belt to carry the product to the
final installation site.
Only lift the product from the back and side where the
hydraulic connections are located.
When transporting the product using a hand truck, secure
the product using a belt.
In order to avoid scratches and damage, protect the
sides of the product that come into contact with the hand
truck.
0020147164_09 aroTHERM Installation instructions
Assembly and installation 5
5.1.1.2 Unpacking the product
B
D
4
E
1.
Remove the accessory (2).
2.
Remove the documentation supplied (1).
3.
Remove the transport belt (4).
4.
Carefully remove the packaging and padding without
damaging the product (3).
5.
Remove the screws from the pallet at the front and rear
of the product.
5.1.1.3 Checking the scope of delivery
Check the contents of the packaging units
Quant-
Description
ity
1
Condensate discharge
1
Bag with seals
4
Vibration-isolating feet
1
Purge hose
13mm
2
1
A
3
C
9