Lark 18S loudspeaker system basic optimization data V1.1
Outward
Model
Amplifier
Lark 2400(Input sensitivity 1.0V)or Lark 3600(Input sensitivity 1.4V)
Controller
Limiter
Ratio: Limit
Xover
HPF: 19.7 Hz
PEQ1
Freq: 38.5 Hz
PEQ2
Freq: 65.5 Hz
Delay
Polarity
Level
Lark 18S
Lark 88
Threshold: +1 dB
Type: Bypass
LPF: 86.4~99.2 Hz
Gain: +4 dB
Gain: -4 dB
None
Normal
0 dB
14
Attack: 50 ms
Release: 500 ms
Type: LK-24 dB
Q: 5
Q: 4
Type: Peak
Type: Peak