Honeywell T8611M Installation Instructions Manual page 7

Deluxe programmable heat pump thermostats
Hide thumbs Also See for T8611M:
Table of Contents

Advertisement

Installer Setup
Number (Press
Time
Select
change)
Minimum off
time for the
compressor.
Temperature
range stops in
heating.
Temperature
range stops in
cooling.
Not Used.
Temperature
display
adjustment.
Furnace Air
Filter Timer.
Humidifier Pad
Monitor.
Ultraviolet (UV)
Air Treatment
System Lamp
Monitor.
IMPORTANT
Review the settings to confirm that they match
the system. Press Run Program to exit the
Installer Setup. The thermostat has saved the
Installer Setup changes and initiated a reset in
order to operate using the new settings. Be sure
to set the current day and time immediately.
Table 3. Thermostat Installer Setup Options. (Continued)
Factory Setting
key to
Display
33
5
5 minutes
minimum off time
for the
compressor.
34
90
Highest heating
setpoint setting.
35
45
Lowest cooling
setpoint setting.
36
37
0
No difference in
displayed
temperature and
actual room
temperature.
43
2
30 days (System
run time)
44
0
Off
45
0
Off
T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
Description
Display
0 thru 4
40 to 89
46 to 99
-3 thru 3
0, 1, 3, 4
1, 2, 3
7
Other Choices
(Press s or t key to change)
Description
Minimum number of minutes
(0 thru 5) the compressor is
off between calls for the
compressor.
Temperature range (1°F
increments) of heating
setpoint settings.
Temperature range (1°F
increments) of cooling
setpoint settings.
1—Display adjusts to 1°F
higher than actual room
temperature.
2—Display adjusts to 2°F
higher than actual room
temperature.
3—Display adjusts to 3°F
higher than actual room
temperature.
-1—Display adjusts to -1°F
lower than actual room
temperature.
-2—Display adjusts to -2°F
lower than actual room
temperature.
-3—Display adjusts to -3°F
lower than actual room
temperature.
0 – off
1 – 10 days
3 – 60 days
4 – 120 days
(Time is counted when heat,
cool or fan running.)
1 – 90 days
2 – 180 days
3 – 365 days
(Time is counted by calendar
days in heat mode.)
1
1 – 365 days
(Time is counted by calendar
days in any mode.)
Actual
Setting
69-1415—1