APPLICATION
The T8611M Deluxe Programmable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two
compressor or two speed heat pump systems with auxiliary heat. The T8611M can be configured to run a single
compressor heat pump system. Refer to Table 1 for a general description of the thermostat. All T8611 thermostats
require a common wire to supply power.
T8611
Changeover
M
Automatic
MERCURY NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.
Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
® U.S. Registered Trademark
Copyright © 2002 Honeywell •
T8611M Deluxe Programmable
Heat Pump Thermostats
Table 1. Description of T8611 Thermostats.
System Selection
Em Heat-Heat-Off-Cool-Auto
• All Rights Reserved
INSTALLATION INSTRUCTIONS
Fan
Selection
On-Auto
Down-selectable for single-compressor
systems.
3. Installer must be a trained, experienced service
technician.
4. After completing installation, use these instructions
to check out the product operation.
Location
Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.
Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall
behind the thermostat.
Comments
69-1415—1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell T8611M

  • Page 1 The T8611M Deluxe Programmable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed heat pump systems with auxiliary heat. The T8611M can be configured to run a single compressor heat pump system. Refer to Table 1 for a general description of the thermostat. All T8611 thermostats require a common wire to supply power.
  • Page 2: Wallplate Installation

    T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Wallplate Installation The thermostat can be mounted horizontally on the wall or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box. Position wallplate horizontally on the wall or on a 2 in.
  • Page 3 WIRE EQUIPMENT MONITOR OR DEFROST RESET CONTROL PER MANUFACTURER INSTRUCTIONS. CONFIGURE IN INSTALLER SETUP. Fig. 3. Typical hookup in heat pump application with emergency heat relay and O/B terminal. T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS OUTDOOR TEMPERATURE SENSOR EQUIPMENT MONITOR 2 Fig.
  • Page 4: Temperature Settings

    DECREASE TIME SETTING OR SCROLL BACKWARD THROUGH INSTALLER SETUP AND SYSTEM TEST Fig. 7. T8611M key locations and descriptions. System settings control the thermostat operation: Em Heat: Defrost reset output relay (L) is on Heat: The thermostat controls the heating.
  • Page 5: Installer Setup

    Settings Daylight Copy Time Fig. 8. T8611M System and Fan key locations. LED Indication Two LED indicators are located in the upper right of the thermostat. They indicate when a CHECK or FAIL signal is sent to the thermostat from the system. See Fig. 9. The CHECK LED is on continuously when the thermostat system setting is in the Emergency Heat position.
  • Page 6 T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Installer Setup Number (Press Time key to Select change) Not Used. 1 thru 4 Number of compressor stages. Heating cycle. Not Used. Not Used. 8 thru 11 System setting adjustment Adaptive Intelligent Recovery™ control.
  • Page 7 Installer Setup. The thermostat has saved the Installer Setup changes and initiated a reset in order to operate using the new settings. Be sure to set the current day and time immediately. T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Factory Setting Display Description...
  • Page 8: Setting Current Day And Time

    T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Setting Current Day and Time 1. Press Set Current Day/Time. NOTE: On initial powerup or after an extended power loss, 1:00 pm flashes on the display until a key is pressed. Set Current Time...
  • Page 9 NOTE: Press any key and the displayed numbers change. Press Time the next test. The Run Program key does not exit this test. Press Time Run Program key to exit. T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS System Em Heat Cool...
  • Page 10: Thermostat Information

    T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS THERMOSTAT INFORMATION 1. Press the Time key to access the thermostat information. 2. Press the increase s key to display the production date code. The first two large digits are the month and the third digit is the last digit of the year.
  • Page 11: Troubleshooting Guide

    System selection is not set to Cool. Cool setpoint is above room temperature. T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Table 6. Troubleshooting Guide. • Check for 24 Vac between R and C terminals. — If missing 24 Vac: — check if the circuit breaker is tripped—reset the circuit breaker.
  • Page 12 T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Symptom Possible Cause System on indicator Heating or cooling equipment is (flame=heat, not operating. snowflake=cool) is displayed, but no warm or cool air is coming from the registers. Outdoor tempera- Option not activated. ture not displayed...