Introduction - Hitachi CP-X200 Instruction Manual

X200 series
Hide thumbs Also See for CP-X200:
Table of Contents

Advertisement

B − 2
B 2

Introduction

X200 Series inverters have built-in RS-485 serial communications, featuring the
ModBus RTU protocol. The inverters can connect directly to existing factory networks
or work with new networked applications, without any extra interface equipment. The
specifications for X200 serial communications are in the following table.
Transmission speed
Communication mode
Character code
LSB placement
Electrical interface
Data bits
Parity
Stop bits
Startup convention
Wait time for response
Connections
Connector
Error check
The network diagram below shows a series of inverters communicating with a host
computer. each inverter must have a unique address, from 1 to 32, on the network. In a
typical application, a host computer or controller is the master and each of the
inverter(s) or other devices is a slave.
Item
4800 / 9600 / 19200 bps
Asynchronous
Binary
Transmits LSB first
RS-485 differential transceiver
8-bit (ModBus RTU mode)
None / even / odd
1 or 2 bits
One-way start from host device
0 to 1000 msec.
Station address numbers from 1 to 32
RS45 modular jack
Overrun, Fleming block check code,
CRC-16, or horizontal parity
Specifications