Omron R3 Instruction Manual

Omron R3 Instruction Manual

Wrist blood pressure monitor
Hide thumbs Also See for R3:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
OMRON HEALTHCARE Co., Ltd.
Manufacturer
53, Kunotsubo, Terado-cho, Muko, Kyoto,
617-0002 JAPAN
OMRON HEALTHCARE EUROPE B.V.
EU-representative
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS
www.omron-healthcare.com
OMRON (DALIAN) CO., LTD.
Production facility
Oficina de producción
Dalian, CHINA
Site de production
Productiefaciliteit
Produktionsstätte
Производственное подразделение
Stabilimento di produzione
OMRON HEALTHCARE UK LTD.
Subsidiary
Empresa filial
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.K.
Succursale
Dochteronderneming
Niederlassung
Дочерняя компания
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
Consociata
John-Deere-Str. 81a, 68163 Mannheim, GERMANY
www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE
Uniquement pour le marché français: OMRON Service Après Vente
Nº Vert 0 800 91 43 14
consommateurs@omron-sante.fr
www.omron-sante.fr/contact
Made in China
Fabriqué en Chine
Hergestellt in China
Prodotto in Cina
Wrist Blood Pressure Monitor
Model R3
Instruction Manual
Fabricado en China
Geproduceerd in China
Сделано в Китае
Check following components!
Vérifier les composants suivants !
Controleer de volgende onderdelen!
Prüfen Sie folgende Teile des Lieferumfangs!
Проверьте следующие компоненты!
Controllare i componenti indicati di seguito!
¡Compruebe los siguientes componentes!
English
Français
Deutsch
Italiano
Español
Nederlands
Русский
IM-HEM-6200-E-03-10/2011
5329513-9B

Advertisement

Table of Contents
loading

Summary of Contents for Omron R3

  • Page 1 Italiano www.omron-medizintechnik.de OMRON SANTÉ FRANCE SAS Español Wrist Blood Pressure Monitor 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE Uniquement pour le marché français: OMRON Service Après Vente Nederlands Model R3 Nº Vert 0 800 91 43 14 consommateurs@omron-sante.fr Русский...
  • Page 2: Table Of Contents

    Thank you for purchasing the OMRON R3 Wrist Blood Pressure Monitor. The OMRON R3 is a compact and easy to use blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the devices uses its advanced “IntelliSense”...
  • Page 3: Important Safety Information

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 1 ページ 2011年10月3日 月曜日 午後6時25分 Important Safety Information Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Please read this section carefully before using the unit. Warning: • Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 4 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 2 ページ 2011年10月3日 月曜日 午後6時25分 Important Safety Information • Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit. •...
  • Page 5: Overview

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 3 ページ 2011年10月3日 月曜日 午後6時25分 1. Overview Open the rear cover page to read following: The alphabet in the rear cover page correspond to those in the body page. Main unit Display Display Systolic blood pressure...
  • Page 6: Preparation

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 4 ページ 2011年10月3日 月曜日 午後6時25分 2. Preparation 2.1 Installing/Replacing the Batteries Remove the battery cover. Push the hook on the bottom of the battery cover.
  • Page 7: Setting The Date And Time

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 5 ページ 2011年10月3日 月曜日 午後6時25分 2. Preparation 2.2 Setting the Date and Time Set the monitor to the correct date and time before taking a measurement for the first time. Press the button.
  • Page 8: Using The Unit

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 6 ページ 2011年10月3日 月曜日 午後6時25分 3. Using the Unit Open both the front and rear covers to read following: The alphabet and number in the cover page correspond to those in the body page. 3.1 Applying the Wrist Cuff Do not apply over clothing.
  • Page 9: How To Sit Correctly

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 7 ページ 2011年10月3日 月曜日 午後6時25分 3. Using the Unit 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. No eating, smoking or exercising 30 minutes before taking a measurement. •...
  • Page 10: Taking A Reading

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 8 ページ 2011年10月3日 月曜日 午後6時25分 3. Using the Unit 3.3 Taking a Reading Notes: • To cancel a measurement, press the O/I START button at any time during measurement. • Remain still while taking a measurement.
  • Page 11 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 9 ページ 2011年10月3日 月曜日 午後6時25分 3. Using the Unit Important: • Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home. Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg...
  • Page 12: Using The Memory Function

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 10 ページ 2011年10月3日 月曜日 午後6時25分 3. Using the Unit 3.4 Using the Memory Function The monitor automatically stores the result up to 60 sets. It can also calculate an average reading based on the measurements from the last three readings taken within 10 minutes. If there are only two readings in memory for that period, the average will be based on two readings.
  • Page 13 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 11 ページ 2011年10月3日 月曜日 午後6時25分 3. Using the Unit To delete all the values stored in memory When the memory symbol ( ) appears, first press the MEM button. Then while holding it down, press the O/I START button simultaneously for about 2-3 seconds.
  • Page 14: Troubleshooting And Maintenance

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 12 ページ 2011年10月3日 月曜日 午後6時25分 4. Troubleshooting and Maintenance 4.1 The Icons and Error Messages Error Display Cause Remedy Remove the wrist cuff. Wait 2-3 minutes and then take another...
  • Page 15 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 13 ページ 2011年10月3日 月曜日 午後6時25分 4. Troubleshooting and Maintenance Error Display Cause Remedy Cuff is over inflated.
  • Page 16: Troubleshooting

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 14 ページ 2011年10月3日 月曜日 午後6時25分 4. Troubleshooting and Maintenance 4.2 Troubleshooting Problem Cause Remedy The wrist cuff is not at heart Measure while in the correct level. posture. Refer to section 3.2.
  • Page 17 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 15 ページ 2011年10月3日 月曜日 午後6時25分 4. Troubleshooting and Maintenance Problem Cause Remedy Blood pressure readings constantly vary with time of day and how relaxed you The blood pressure is different each time. The reading is are.
  • Page 18: Maintenance

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 16 ページ 2011年10月3日 月曜日 午後6時25分 4. Troubleshooting and Maintenance 4.3 Maintenance To protect your unit from damage, please avoid the following: • Subjecting your unit to extreme temperatures, humidity, or direct sunlight. • Washing the cuff or exposing the cuff or unit to water. •...
  • Page 19 • The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. • It is generally recommended to have the unit inspected every two years to ensure correct functioning and accuracy. Please consult your authorised OMRON dealer or...
  • Page 20: Technical Data

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 18 ページ 2011年10月3日 月曜日 午後6時25分 5. Technical Data Product Description Wrist Blood Pressure Monitor Model OMRON R3 (HEM-6200-E/HEM-6200-E8) Display LCD Digital Display Measurement Method Oscillometric method Measurement Range Pressure: 0 mmHg to 299 mmHg Pulse: 40 to 180 beats/min.
  • Page 21 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 19 ページ 2011年10月3日 月曜日 午後6時25分 5. Technical Data Approximately 71 (w) mm  41 (h) mm  70 (d) mm Outer Dimensions without the wrist cuff Measurable circumference Approximately 13.5 to 21.5 cm of wrist Cuff Material Nylon and polyester Package Content...
  • Page 22 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 20 ページ 2011年10月3日 月曜日 午後6時25分 5. Technical Data Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation.
  • Page 23: Some Useful Information About Blood Pressure

    All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 21 ページ 2011年10月3日 月曜日 午後6時25分 6. Some Useful Information about Blood Pressure What is Blood Pressure? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cycle. The highest pressure in the cycle is called the Systolic Blood Pressure;...
  • Page 24 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 22 ページ 2011年10月3日 月曜日 午後6時25分 6. Some Useful Information about Blood Pressure Why is it a Good Thing to measure Blood Pressure at Home? Many factors such as physical activity, anxiety, or Upper curve: systolic blood pressure Lower curve: diastolic blood pressure the time of day, can influence your blood pressure.
  • Page 25 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 23 ページ 2011年10月3日 月曜日 午後6時25分 6. Some Useful Information about Blood Pressure Classification of Blood Pressure by the World Health Organization The World Health Organization (WHO) and the Systolic blood pressure International Society of Hypertension (ISH) (mmHg) developed the Blood Pressure Classification Severe hypertension...
  • Page 26 All manuals and user guides at all-guides.com HEM-6200-E_D_M_main.book 24 ページ 2011年10月3日 月曜日 午後6時25分...

Table of Contents