oiling stapler
place one or two drops of pneumatic tool oil
in the stapler air inlet (as shown in figure
1) before every use. Wipe off any excess
oil near the stapler exhaust to avoid dust
build-up.
figure 1. lubricating stapler via air inlet.
another option to manual oiling would be
to install a lubricator in your air compressor
line. if your air compressor line already has
a lubricator, then regular lubrication of your
stapler will not be necessary. Just make
sure there is always pneumatic tool oil in
the lubricator.
as mentioned before, the best option is to
install a filter/lubricator/regulator unit such
as those found in the grizzly catalog.
-6
-

operation

loading stapler
When replacing staples in your model
h5977, follow these guidelines:
gauge: 15
1
2
staple sizes: 1"–2"
Capacity: 60
to load your stapler:
1.
disconnect the air supply from the
stapler!
2.
slide back the magazine loading han-
dle until it locks.
3.
load a staple stick in the t-slot at
the top of the magazine as shown in
figure 2.
4.
release the magazine loading handle
by pulling it back, then letting go.
figure 2. loading staples into stapler.
Model h5977 (Mfg. since 2/07)