Model Number Nomenclature; Ari* Capacities; Cooling Capacities And Efficiencies; Heating Capacities And Efficiencies - Carrier 50XT Product Data

15 seer single-packaged heat pump system with puron (r-410a) refrigerant single phase 2-5 nominal tons
Hide thumbs Also See for 50XT:
Table of Contents

Advertisement

MODEL NUMBER NOMENCLATURE

Type of Unit
50XT - Packaged
Electric Heat Pump
Nominal Cooling Capacity
024 - 2 Ton
030 - 2.5 Ton
036 - 3 Ton
042 - 3.5 Ton
048 - 4 Ton
060 - 5 Ton
N/A
LEGEND
AL - Aluminum
CU - Copper

ARI* CAPACITIES

Cooling Capacities and Efficiencies

UNIT
NOMINAL
STANDARD CFM (High/Low Stage)
50XT
TONS
024
2
030
2- -1/2
036
3
042
3- -1/2
048
4
060
5

Heating Capacities and Efficiencies

HIGH HEAT CAPACITY
UNIT
(BTUH) @ 47°F (8.3°C)
50XT
(High/Low Stage)
024
20,800 / 16,800
030
27,600 / 20,400
036
33,600 / 23,000
042
39,500 / 27,600
048
45,500 / 32,200
060
56,000 / 39,500
"A" conditions---80°F (26.6°C) indoor db/67°F (19.4°C) indoor wb & 95°F (35°C) outdoor db.
{
Rated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or ARI Standards 210/240.
}
** Tested in accordance with ARI Standard 270 ---95 (not listed in ARI).
NOTES:
1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on:
Cooling Standard: 80°F (26.6°C) db, 67°F (19.4°C) wb indoor entering ---air temperature and 95°F (35°C) db outdoor entering---air temperature.
2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
LEGEND
dBA—Sound Levels (decibels)
db—Dry Bulb
SEER—Seasonal Energy Efficiency Ratio
wb—Wet Bulb
COP—Coefficient of Performance
HSPF—Heating Season Performance Factor
50XT
024
– – –
3
Electrical Supply
3- 208/230-1-60
NET COOLING CAPACITIES (Btuh)
(Cooling & Heating)
800 / 600
1000 / 700
1200 / 850
1500 / 975
1600 / 1100
1750 / 1200
HIGH HEAT COP
LOW HEAT CAPACITY
@ 47°F (8.3°C)
(BTUH) @ 17°F (- - 8.3°C)
(High/Low Stage)
3.3 / 3.2
3.5 / 3.5
3.4 / 3.4
3.6 / 3.5
3.3 / 3.5
3.2 / 3.3
0
1
– –
Options
BT - AL evap, vinyl condens
CC - AL evap, CU condens
CU - CU evap & condens
TP - Base unit with tin plated
indoor coil hairpins
TV - TP with vinyl coating on outdoor coil
TC - TP with AL indoor coil and
CU/CU outdoor coil
Only used if ordering an option
Packaging
Series
(High/Low Stage)
22,600 / 17,600
28,600 / 21,400
34,600 / 24,400
40,500 / 29,000
46,000 / 33,400
57,000 / 40,500
LOW HEAT COP
@ 17°F (- - 8.3°C)
(High/Low Stage)
(High/Low Stage)
11,600 / 8,400
14,000 / 9,600
17,200 / 11,200
20,600 / 14,200
25,000 / 15,200
30,800 / 20,400
3
EER @A{
SEER‡
11.4
15.5
11.6
15.0
12
15.0
11.6
15.0
11
15.0
11
14.5
HSPF‡
2.2 / 1.8
8.0
2.1 / 1.9
8.0
2.4 / 1.7
8.0
2.3 / 2.0
8.0
2.4 / 1.9
8.0
2.2 / 1.9
8.0

Advertisement