Setup
Fill gear reducer reservoir with
oil
Open the fill cap (FC) and fill the gear reducer oil reser-
voir with 2 quarts (1.9 liters) of Graco 288414 Oil (twelve
1 quart bottles). Check the oil level in the sight glass
(SG) on the gear reducer housing. Do not overfill. See
F
. 5.
IG
NOTE: 2 quarts brings oil level above sight glass (SG)
when off, but level drops when operating.
FC
SG
F
. 5. Oil Fill
IG
311593R
Fill TSL Reservoirs
Part No. 206995 Throat Seal Liquid (TSL) carries resi-
due from the pump rod into the reservoir. Fill the TSL
reservoirs (R) with Graco 206994 Throat Seal Liquid
(TSL). See F
for fill instructions.
R
F
. 6. Fill TSL Reservoirs
IG
Flush before using equipment
ti8914a
The equipment was tested with Stoddard Solvent, which
is left in the fluid passages to protect parts. To avoid
contaminating your fluid with solvent, flush the equip-
ment with a compatible solvent or water before using the
equipment. See Flushing, page 17.
. 6. See Changing the TSL on page 17
IG
Setup
R
ti8915b
13