Feature
Feature Description
The compressor short cycle delay protects
Compressor
the compressor from short cycling. This
feature will not allow the compressor to
Short Cycle
be turned on for 5 minutes after it was
Delay
last turned off.
The differential or swing setting, often
called cycle rate or anticipation, is
Cooling
adjustable. A smaller differential setting
Differential or
will cause more frequent cycles and
Swing
a larger differential setting will cause
fewer cycles.
The differential or swing setting, often
Heating
called cycle rate or anticipation, is
adjustable. A smaller differential setting
Differential or
will cause more frequent cycles and
Swing
a larger differential setting will cause
fewer cycles.
TECHNICIAN SETUP MENU
LCD will show Adjustment Options
Selecting ON will not allow
Next Step
the compressor to be turned on for
Com Delay
5 minutes after the last time the
compressor was on. Select OFF to
Prev Step
remove this delay.
Done
The cooling differential setting is
adjustable from ± 0.2°F to ± 2°F.
For example: A differential setting
Next Step
of 0.5°F will turn the cooling on
Cool Swing
at approximately 0.5°F above the
setpoint and turn the cooling off
Prev Step
at approximately 0.5°F below the
Done
setpoint.
The heating differential setting is
adjustable from ± 0.2°F to ± 2°F.
For example: A differential setting
Next Step
Heat
of 0.5°F will turn the heating on
Swing
at approximately 0.5°F below
Prev Step
the setpoint and turn the heating
Done
off at approximately 0.5°F above the
setpoint.
Factory default
settings
15