sEctioN 6.1
maJor DisassEmBlY
8. Loosen side panel: Using a 10mm socket remove the
two bolts from the base of the enclosure side panel. See
Figure 10.
9. Unbolt enclosure side panel mounting bracket: Using a
10mm socket remove the two bolts from the enclosure
side panel mounting bracket. See Figure 11.
Figure 10.
Figure 11.
Page 154
Part 6
10. Remove fuel regulator: Remove the two fuel hoses at
the top of the regulator. Using a 10mm socket remove
one 10mm bolt from the base of the plenum and one
10mm bolt from the base of the fuel regulator. Flex
the enclosure side out to allow for room to remove the
regulator assemble. See Figure 12.
Figure 12.
11. Remove engine divider panel: Using a 10mm socket
remove the rear 10mm bolt from the base of the
enclosure. See Figure 13. Remove the front 10mm
bolt from the base of the enclosure. See Figure 14.
Figure 13.