Maintenance
Oetiker Clamp Servicing
WARNING
DO NOT re-use Oetiker clamps. Fuel leakage
could contribute to a fire or explosion.
See the Oetiker Clamp Chart on p. 54.
Clamp Identification
Use Oetiker clamps for making hose connections.
These clamps provide corrosion resistance, mini-
mize the potential for abrasion of rigging compo-
nents, and provide solid, permanent connections.
The selection and installation of an Oetiker clamp
is essential in the proper sealing of hose connec-
tions.
The clamp identification numbers appear on the
side of the clamp, near the top of the ear. Refer to
Oetiker Clamp Chart on p. 54 chart for clamp
dimensions.
1
1. Clamp identification numbers
Clamp Selection
To select the correct size Oetiker clamp, measure
the outside diameter of the hose when installed on
the fitting.
Chose a clamp so that the outside diameter of the
hose is approximately in the middle of the clamp-
ing range of the clamp.
Refer to Oetiker Clamp Chart on p. 54.
18
Clamp Installation
A constant stress should be applied to close the
ear clamps. This method ensures a positive stress
on the hose and does not result in excessive com-
pression or expansion of the band material.
IMPORTANT:
tools to close Oetiker stepless clamps.
Oetiker pincers, P/N 787145, are available in the
Evinrude Genuine Parts and Accessories Catalog.
•
Position correct size clamp over hose.
•
Install hose on fitting.
Larger size Oetiker clamps may come apart
during handling. To reassemble the clamp, con-
nect the end loop to the end hook. Make sure the
alignment tab is installed into the alignment slot.
4
000093
3
1. End loop
2. End hook
3. Alignment tab
4. Alignment slot
5. Correctly assembled clamp
Use only Oetiker recommended
3
4
1
2
787145
5
009095