Fuse Replacement; Fan Replacement - Furuno CSH-5L/CSH-8L Operator's Manual

Color scanning sonar
Table of Contents

Advertisement

8. MAINTENANCE, TROUBLESHOOTING
8.4

Fuse Replacement

The fuses in the processor and transceiver units protect them from overvoltage,
equipment fault and reverse polarity of the ship's mains. If the power cannot be
applied, first check the fuse for the processor unit. The fuse for the transceiver
unit is inside the unit; have a qualified technician check the fuse. If a fuse blows
after replacement, or the power cannot be turned in spite of normal fuse, contact
your dealer for advice.
8.5

Fan Replacement

The processor unit has a fan, and its life is about 25,000 hours, in ambient
temperature of 50°C.
If the fan stops, because the area around the power supply is too hot, the power
voltage may fluctuate. Contact a FURUNO agent or dealer to request
replacement of the fan.
Fan
8-4
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment.
Unit
Processor Unit
Transceiver Unit
(100 VAC spec.)
Transceiver Unit
(220 VAC spec.)
Type
Code No
109-180
000-105-416
Fuse Type
FGBO-A 2A AC125V
FGMB 2A 250V
FGBO 7A AC125V
FGMB 2A 250V
FGBO 4A AC250V
Code No.
000-549-062
000-122-000
000-549-013
000-122-000
000-546-707