5.4.1 Filter Operation (cont.)
8. Begin the filtering process by pulling the
yellow handle to open the oil-return valve
(this activates the filter pump automatically).
9. Oil will begin to pump from the filter pan
into the frypot. Allow the oil to circulate
through the frypot for the remainder of the
timed
countdown
minutes).
This process is known as
"polishing".
10. The computer will display FILL at the end
of the timed countdown. Replace the frypot
grid rack. Close the red drain valve handle to
begin refilling the frypot.
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 5: FILTRATION OPERATION
(approximately
10
Begin the filtering process by pulling yellow handle
to open oil return valve. Leave the drain valve
(red handle) open during the filtering process.
Polishing the oil removes suspended particles,
which increases the life of the oil.
When the computer displays FILL, close the
drain valve to begin refilling the frypot.