Table 6 — 30XA080-500 Electrical Data, Dual Point (Standard Condenser Fan Motors) (cont)
UNIT VOLTAGE
UNIT
Supplied
V-Hz
30XA
(3 Ph)
Min
Max
230-60
207
253
200-60
187
220
080
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
090
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
100
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
110
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
120
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
140
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
160
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
180
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
200
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
220
460-60
414
506
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
240
460-60
414
506
575-60
518
633
380-60
342
418
460-60
414
506
260
575-60
518
633
380-60
342
418
460-60
414
506
280
575-60
518
633
380-60
342
418
460-60
414
506
300
575-60
518
633
380-60
342
418
460-60
414
506
325
575-60
518
633
380-60
342
418
460-60
414
506
350
575-60
518
633
380-60
342
418
460-60
414
506
400
575-60
518
633
380-60
342
418
460-60
414
506
450
575-60
518
633
380-60
342
418
460-60
414
506
500
575-60
518
633
380-60
342
418
LEGEND
ICF
— Instantaneous Current Flow
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
WD
— Wye-Delta
XL
— Across-the-Line
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit
terminals is not below or above the listed minimum and maximum limits. Maximum
allowable phase imbalance is: voltage, 2%; amps 10%.
2. Cooler heater is wired into the control circuit so it is always operable as long as the
control power supply disconnect is on, even if any safety device is open.
3. For MCA that is less than or equal to 380 amps, 3 conductors are required.
NUMBER
OF
COND
MCA
MOCP
FANS
3/3
182.9/227.9
300/350
3/3
201.5/251.2
300/350
3/3
91.4/113.9
150/175
3/3
70.3/ 88.3
110/125
3/3
106.5/133.7
175/200
4/4
199.9/244.9
300/350
4/4
220.0/269.8
350/400
4/4
99.9/122.4
150/175
4/4
76.4/ 94.4
125/125
4/4
116.5/143.8
175/225
4/4
241.0/244.9
400/350
4/4
264.9/269.8
450/400
4/4
120.0/122.4
200/175
4/4
92.5/ 94.4
150/125
4/4
140.2/143.8
225/225
4/4
241.0/286.0
400/450
4/4
264.9/314.7
450/500
4/4
120.0/142.5
200/225
4/4
92.5/110.5
150/175
4/4
140.2/167.5
225/250
4/4
370.0/244.9
600/350
4/4
407.2/269.8
700/400
4/4
185.0/122.4
300/175
4/4
141.9/ 94.4
225/125
4/4
215.1/143.8
350/225
6/4
423.5/286.0
700/450
6/4
465.6/314.7
800/500
6/4
211.3/142.5
350/225
6/4
162.2/110.5
250/175
6/4
246.0/167.5
400/250
6/4
6/4
6/4
6/4
6/4
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
9/6
9/6
9/6
9/7
9/7
9/7
10/6
10/6
10/6
9/9
9/9
9/9
9/9
9/9
9/9
8/12
8/12
8/12
8/14
8/14
8/14
8/14
8/14
8/14
15 HP PUMP, 3450 RPM
ICF
WD
348.0/393.0
1034.0/1079.0
399.5/449.3
1188.5/1238.3
174.0/196.5
517.0/ 539.5
139.6/157.6
413.6/ 431.6
210.5/237.8
625.5/ 652.8
372.0/417.0
1114.0/1159.0
426.5/476.3
1280.5/1330.3
186.0/208.5
557.0/ 579.5
148.6/166.6
445.6/ 463.6
225.5/252.8
674.5/ 701.8
372.0/417.0
426.5/476.3
186.0/208.5
557.0/ 579.5
148.6/166.6
445.6/ 463.6
225.5/252.8
674.5/ 701.8
372.0/417.0
426.5/476.3
186.0/208.5
557.0/ 579.5
148.6/166.6
445.6/ 463.6
225.5/252.8
674.5/ 701.8
632.0/417.0
724.8/476.3
316.0/208.5
948.0/ 579.5
252.4/166.6
758.4/ 463.6
382.8/252.8
1147.8/ 701.8
800.0/417.0
918.8/476.3
400.0/208.5
1208.0/ 579.5
320.4/166.6
966.4/ 463.6
483.8/252.8
1462.8/ 701.8
For MCA between 381-760 amps, 6 conductors are required.
For MCA between 761-1140 amps, 9 conductors are required.
For MCA between 1141-1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
4. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage)
to 500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is
3/0 to 500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps
is 1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps
is 250 kcmil to 500 kcmil.
5. Data provided circuit 1/circuit 2 where there are two circuits.
68
CONTROL CIRCUIT
Rec
Voltage
Fuse
1 PH,
XL
Size
60 Hz
225/300
115
250/300
115
110/150
115
90/110
115
125/175
115
250/300
115
300/350
115
125/150
115
90/110
115
150/175
115
300/300
115
350/350
115
150/150
115
110/110
115
175/175
115
300/350
115
350/400
115
150/175
115
110/150
115
175/200
115
450/300
115
500/350
115
225/150
115
175/110
115
300/175
115
600/350
115
600/400
115
250/175
115
200/150
115
300/200
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
MCA
and
MOCP
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50