Siemens SIMATIC NET RUGGEDCOM RX1510 Installation Manual page 50

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1510:
Table of Contents

Advertisement

4.
Disconnect the power supply wiring from the terminal block. Alternatively, for
convenience, remove the terminal block with the wiring still connected and set
it aside to be connected later to the new module.
5.
Install a new or blank module to prevent the ingress of dust and dirt.
Installing a Power Module
To install a power module, do the following:
1.
If equipped, remove the existing module.
2.
If applicable, connect the supplied terminal block to the module or connect the
terminal block from the previous module.
3.
Confirm or connect the wiring from the power supply to the module. For more
information, refer to
4.
Insert the module into the empty slot.
Figure 4.6
5.
Hand-tighten the screws to secure the power module to the chassis.
6.
Turn on power to the device and confirm the module is receiving and supplying
power. This is indicated by the LEDs on the module.
RUGGEDCOM RX1510
Installation Manual, 12/2019, C79000-G8976-1055-16
All manuals and user guides at all-guides.com
"Connecting Power (Page
Chassis
1
Screws
2
Power Module
3
Installing a Power Module
LED
State
O
Green
I
Green
4.3 Installing/Removing Power Modules
9)".
Description
The module is supplying power
The module is receiving power
Modules
1
2
3
41