Installation Procedure

It is essential to observe minimum wall mounting clearances - see Fig. 1.
The appliance should be fitted horizontally, with the cable entry at the top
and grille at the bottom. It must be mounted not less than 1800mm above
the floor with a clearance of at least 600mm to any shelf or projecting
surface below the heater and not less than 300mm below the ceiling or
other projecting surface. It must also be not less than 250mm from an
adjacent projecting surface. For most effective heating performance, the
heater should be mounted at the minimum height :-
i.e.- 1800mm above the floor.
Care must be taken to ensure that when in use, the air stream is not
obstructed by a high shelf or cabinet.
The appliance is secured to the wall with three screws, two through
keyhole slots and one through a centrally positioned lower hole to hold
the appliance firmly in position (see Fig. 2).
1.
Remove the top cover from the appliance by removing the two
screws securing the top cover and hinging it back.
2.
Mark the position of the keyhole slots on the wall and drill and plug
for the two suitable screws.
3.
Partially insert the two screws, then hang the appliance on these
screws and mark the position of the lower centrally positioned screw.
4.
Remove the appliance and drill and plug for the third screw.
5.
Remount the appliance on the wall, ensure that it is horizontal and
fix in position by tightening all three screws.
6.
Feed the supply cord or wires through the inlet at the top rear of the
appliance leaving sufficient free length to connect to the terminal
block.
7.
Make electrical connections to the terminal block ensuring that the
live connection is made to the terminal marked 'L' and the neutral
connection to the terminal marked 'N' (see Fig. 2 exploded view).
8.
Operate the selector switch to provide either 1kW or 2kW output.
9.
Replace the top cover and screws.
The appliance is now ready for use and the electricity supply can be
reinstated.
M
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC)
EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336
Glen Dimplex UK Limited
Millbrook House
Grange Drive
Hedge End
Southampton
Hampshire. SO30 2DF
[c] Glen Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.
Fig. 2
Fig. 3 - FX20V Wiring Diagram
UK customer help line 8.00am–5.00pm Mon-Fri and 8:30am-1.00pm Sat (Autumn–Winter only)
Customer Services:
Republic of Ireland
FX20V Controls
The heater is fitted with a pull cord
operated ON/OFF switch, a thermostat, a
cut-out, and a thermal fuse link.The
heater has an internal adjustable
thermostat which can be adjusted by
installer (i.e. the top cover has to be
removed), see Fig. 4 for controls details
with cover removed. Temp. range 18°C -
32°C.
Cleaning and User Maintenance
WARNING
BEFORE UNDERTAKING CLEANING OR MAINTENANCE WORK ON THE
APPLIANCE IMMEDIATELY DISCONNECT THE ELECTRICITY SUPPLY
BY SWITCHING OFF AT THE ADJACENT DOUBLE POLE SWITCH.
The outside can be cleaned by wiping it over with a soft damp cloth and
then dried. Do not use abrasive cleaning powders or furniture polish as this
can damage the surface finish.
Ensure that dust or fluff does not accumulate inside the heater as this could
lead to overheating of the element. Use a vacuum cleaner to remove any
fluff which does accumulate.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should not be
disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for
recycling advice in your country.
After Sales Service
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free of
charge subject to availability provided it has been installed and operated
in accordance with these instructions.
Your rights under this guarantee are additional to your statutory rights,
which in turn are not affected by this guarantee.
Should you require after sales service you should contact our customer
services help desk on 0845 600 5111. It would assist us if you can quote the
model number, series, date of purchase, and nature of the fault at the time
of your call. The customer services help desk will also be able to advise you
should you need to purchase any spares.
Please do not return a faulty product to us in the first instance as this may
result in loss or damage and delay in providing you with a satisfactory
service.
Please retain your receipt as proof of purchase.
Tel.
0845 600 5111
Fax.
01489 773053
e-mail customer.services@glendimplex.com
Tel.
01 8424833
selector
switch
internal adjustable
thermostat knob
Fig. 4

Advertisement

loading