2.
Press the UP/DOWN button to select the item EVF. Then press the RIGHT button to enter EVF menu. Menu items are
shown as figure 3.4.3. Press the DISP button to initialize LCD setting.
Fig. 3.4.3
3.
Press the UP/DOWN button to select the item VCO. Press the RIGHT button, then adjustment screen will be changed
to EVF from LCD. If the image on EVF is NG, press MENU button at most 6 times to let it become normal. If it
doesn't work, the camera is NG.
Press the UP button until the upper image twists suddenly. Then press the OK button to set the upper limited value.
Press the DOWN button until the upper image twists again. Then press the OK button to set the lower limited value.
The center value of upper limit and lower limit will be saved and go back to EVF adjusting menu on LCD screen
automatically.
4.
Press the UP/DOWN button to select the item HPOS. Then press the RIGHT button to enter.
Then press the STROBE button and a white frame will be displayed on EVF as figure 3.4.4. Press the UP/DOWN to
adjust the frame of both left-hand side and right-hand side are clear. Then press OK button to return.
Fig. 3.4.4
5.
The setting range of Oscilloscope is AC, 500mV/div, 20us/div for the observation of the waveform of COM signal
(TP704). Press the UP/DOWN button to select the item COM A. Then press the RIGHT button. Then Press UP/DOWN
to set the COM signal waveform peak-peak to 3.5 +/- 0.18V shown as figure 3.4.5. Then press OK button to return.
Fig. 3.4.5
6.
The setting range of Oscilloscope is AC, 500mV/div, 20us/div for the observation of the waveform of G signal (TP702).
Press the UP/DOWN button to select the item U_CNT. Then press the RIGHT button.
Then press UP/DOWN to set G signal shown as figure 3.4.6. The white level to black level peak-peak voltage should
be adjusted 2.3 +/- 0.12V. Then press OK button to return.
3.5Vp-p
24