Toshiba PDR-M70 Service Manual page 28

Hide thumbs Also See for PDR-M70:

Advertisement

Fig. 3.3.2
2. Press the UP/DOWN button to select the item LCD. Then press the RIGHT button to enter LCD menu. Menu items are
shown as figure 3.3.3. Press the DISP button to initialize LCD setting. If the image on LCD is NG, press MENU button at
most 6 times to let it become normal. If it doesn't work, the camera is NG.
Fig. 3.3.3
3. Press the UP/DOWN button to select the item AFC_S. Then press the RIGHT button.
Press the UP button until the upper image twists suddenly. Then press the OK button to set the upper limited value.
Press the DOWN button until the upper image twists again. Then press the OK button to set the lower limited value.
The center value of upper limit and lower limit will be saved and go back to the LCD adjusting menu automatically.
4. The setting range of Oscilloscope is AC, 1V/div, 20us/div for the observation of the waveform of G signal (TP602). Press
the UP/DOWN button to select the item BLIM. Then press the RIGHT button to enter. Press the UP/DOWN to adjust the
waveform to 8 +/- 0.4V shown as Fig. 3.3.4. Then press OK button to return.
Fig. 3.3.4
19
8+/-0.4V