To disassemble the Battery terminals sub-assembly (after step 15)
15a
15a1
15a2
15a3
15a4
15a5
15a6
15a7
The top view of camera
of step 15.
Remove the screws
01635-042*2 of Shutter
PCB ASSY U520 and
take off the Shutter PCB
ASSY.
Remove the screws
01635-010*2 on Mode
PCB ASSY U510.
Desolder the wire joints
as shown.
Pull up the Mode PCB
ASSY U510 after the
solder being cleaned.
Remove the screws
01635-042*2 inside the
Battery Chamber.
Remove the screw
01635-010 outside the
Battery Chamber.
Pull down the Battery
Chamber ASSY as
shown.
Remove the screws
01635-164*4 to separate
the Battery Terminal
A600. The camera
disassemble procedure
is finished.
10
Open the cap of
connector before
Screw driver
remove the Shutter
Tweezers
PCB U520 as
shown.
Screw driver
Soldering iron
Watch out the IR
Receiver ASSY
Tweezers
should not be
damaged.
Screw driver
Screw driver

Advertisement