30
CLEANING & MAINTENANCE
en
REPLACING THE UV LAMP
Before replacing the UV lamp, make sure the
Therapure
®
TPP640S air purifier is turned off and
unplugged. Let the lamp cool down for 5 minutes
before replacing it.
1.
Release the inlet grill by pressing on the locking
latch.
2. Grasp the left and right frames of the filter through
the indentations on the sides of the filter enclosure
and remove filter.
3. Remove the two bolts used to fix the UV lamp cover
and remove the cover out from the unit, then un-
screw the old UV lamp from the lamp base of the
unit.
4. Install the new UV lamp into the lamp base of the
unit.
5. Install the UV lamp cover with the two bolts on the
unit.
6. Install the inlet grill on the unit.