CLEANING & MAINTENANCE

CLEANING THE PRE-FILTER

1.
Release the air inlet grill by pressing on the locking
latch.
2. Gently remove the pre-filter from the air inlet grill.
3. To clean the pre-filter, simply submerge in warm
soapy water. Gently lift and submerge the pre-
filter several times until it is clean.
4. Rinse the pre-filter with clean water and allow it
to dry completely before placing it back to the air
inlet grill.

CLEANING EXTERNAL SURFACES

1.
Turn off and unplug unit.
2. Use a washcloth slightly dampened with a little
water and dishwashing soap to wipe the outer
case surfaces.
3. Do not allow water to slip into the internal parts as
this could damage your unit and result in electrical
shock and injury to you.
4. Allow the unit to thoroughly dry before use.

UV LAMP

The lifetime of the UV lamp is up to 12 months of
continuous, effective operation. After this time,
the bulb may remain illuminated, but its effective-
ness is greatly reduced. For maximum effective-
ness, replace the UV bulb annually.
Do not touch the glass part of the lamp. Oil from
fingertips will decrease the effectiveness of the
lamp.
Never operate the unit without a filter or with a
damaged filter. UV lamp cover must be installed at
all times. The UV light from the UV lamp will result
in severe damage to eyes and could cause blind-
ness.