Conversion To Natural Gas Or To Lpg - CDA RC9321 Manual For Installation, Use And Maintenance

Twin cavity gas cooker
Table of Contents

Advertisement

Conversion to Natural Gas or to LPG

Injectors replacement of
top burners
Every cooker is provided with a set of injec-
tors for the various types of gas.
Injectors not supplied can be obtained
from the After-Sales Service.
Select the injectors to be replaced accord-
ing to the table at page 39.
The nozzle diameters, expressed in hun-
dredths of a millimetre, are marked on the
body of each injector.
To replace the injectors proceed as follows:
Remove the grids and extract the burner
bodies.
Using a wrench, substitute the nozzle
injectors "J" (Figs. 44a - 44b) with those
most suitable for the kind of gas for
which it is to be used (see "Table for the
choice of the injectors").
The burners are constructed in such a
way so as not to require the regula-
tion of the primary air.
Adjusting of the minimum
of the top burners
Considering that in the minimum position
the flame must have a length of about 4
mm and must remain lit even with a quick
turn from the maximum position to that of
minimum.
The flame adjustment is done in the follow-
ing way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a thin screwdriver turn the screw F
until adjustment is correct (fig. 45).
Normally for LPG, tighten up the regu-
lation screw.
38
Fig. 44a
Fig. 44b
Fig. 45
J
J

Advertisement