Troubleshooting
Diagnosis
(cont.)
Fault code System character-
istics
25
No flame signal
after the safety peri-
od; the ionisation
flame monitor re-
ports no flame sig-
nal
26
The ionisation flame
monitor reports ex-
ternal light ingress
during the start or
after the post purge
26
The ionisation flame
monitor reports ex-
ternal light ingress
during the start or
after the post purge
26
The ionisation flame
monitor reports ex-
ternal light ingress
during the start or
after the post purge
26
The ionisation flame
monitor reports ex-
ternal light ingress
during the start or
after the post purge
27
Flame extinguishes
during operation
27
Flame extinguishes
during operation
27
Flame extinguishes
during operation
27
Flame extinguishes
during operation
29
Burner control unit
fault
42
Cause
Remedy
Incorrect para-
Adjust the parameter set
meter set se-
(see page 35 to 36).
lected
Ignition cables
Remove the short cir-
short circuited
cuit.
Short circuit at the
Remove the short cir-
ionisation cables
cuit.
or electrode
Gas combination
Replace the gas combi-
valve leaks
nation valve.
Incorrect para-
Adjust the parameter set
meter set se-
(see page 35 to 36).
lected
Incorrect gas type
Adjust the gas type (see
selected
page 9).
Burner gauze as-
Replace the burner
sembly faulty
gauze assembly.
Incorrect para-
Adjust the parameter set
meter set se-
(see page 35).
lected
Combustion char-
Adjust the burner (see
acteristics not
from page 14).
ideal
Internal fault of
Replace the burner con-
the gas pressure
trol unit.
switch input