Axis Q1715 User Manual page 33

Block camera
Hide thumbs Also See for Q1715:
Table of Contents

Advertisement

AXIS Q1715 Block Camera
Specifications
Audio input
1 Tip
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, trough an event or from the product's webpage.
6-pin terminal block
Function
DC ground
DC output
Configurable
(Input or Output)
Example
1
DC ground
2
DC output 12 V, max 50 mA
3
I/O configured as input
4
I/O configured as output
5
Configurable I/O
6
Configurable I/O
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
2 Ring
33
3 Sleeve
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA

Advertisement

Table of Contents
loading

Table of Contents