Custom Valance to Disguise Outlet – (Optional)
A custom valance may be constructed to obscure the view of the manifold outlet. If using a valance it must meet
the following requirements.
The valance may be constructed of non-combustible or combustible material. All clearances must be
maintained regardless of material.
The top surface of the valance floor must be a minimum of 1-3/8" (35mm) below the top edge of the lower
framing for the manifold (approx. 2-5/8" (67mm) from the bottom of the manifold outlet).
The distance from the front of the manifold opening to the inside surface of the front of the valance must
be a minimum of 6" (153mm).
The front wall of the valance can be a maximum of 6" (153mm) tall (see illustration below).
If the valance has an end cap, the inner surface of the end cap must be a minimum of 6" (153mm) from
the manifold outlets edge.
NOTE: Do not place anything in the valance (artwork, decorations, etc.). Placement of items on the
valance could obstruct the airflow and create a hazardous condition.