3615 HO - Combustible "Over-Facing" (Optional)

When using the CoolSmart TV kit, Combustible material can be installed over the non-combustible board on the
front of the fireplace. To be clear, there will be (2) layers of board over the front of the appliance, one non-
combustible that covers the entire front of the fireplace, and a second layer that can be combustible material
that is placed on top of the non-combustible board.
The combustible material MUST be installed OVER 1/2" of non-combustible board.
WARNING: If using a trim kit or the Gallery face, a ½ " air space is required from all four sides of the tile stop on
the fireplace. If no trim is being used, the airspace is not required (see below for details).
NOTE: The maximum facing depth (combustible + non-combustible facing) is 1-1/4". Any facing that extends
farther than 1-1/4" must meet mantel clearances.
WARNING: The front of the appliance is subject to high temperatures which may cause discoloration and/or
material degradation. Take this into account when choosing finishing materials.
Page 26 of 37
PB 24CF, PB 36CF, 564 25K, 564 35K, 3615HO
WARNING
Over Facing
WITH
Combustible Facing
Allowed
Non-Combustible board
Non-Combustible
Facing Only
Trim Kit
Over Facing
WITH OUT
Combustible Facing
Allowed
Non-Combustible board
Non-Combustible
Facing Only
17602034- 12/13/21
CoolSmart TV
(sku# 98900778)
Trim Kit
OVER
Combustible Facing
Required
1/2" (13mm)
Air Space
Fireplace side
Tile Stop
Trim Kit
OVER
Combustible Facing
Combustible Facing
can be flush with the
Tile Stop on the fireplace
Fireplace side
Tile Stop