Using Oval Pipe To Get Past An Obstruction - FireplaceXtrordinair PB 24CF Manual

Table of Contents

Advertisement

Using oval pipe to get past an obstruction

If a situation arises that obstructs the
CoolSmart flex vent runs (such as
getting past a minimum sideways
vent) you may transition the 5" flex
vent to a ridged nominal 6" oval pipe
to get past the obstruction. Transition
back to the 5" round flex and continue
to the manifold.
The adapters and ridged pipe should
be factory ovalized, not field ovalized.
NOTE: All clearances to combustibles
must be maintained.
Page 37 of 37
PB 24CF, PB 36CF, 564 25K, 564 35K, 3615HO
5"
5"
17602034- 12/13/21
CoolSmart TV
(sku# 98900778)
7-3/4"
3"
7-3/4"
5"
3"
5" Flex
to CoolSmart
Manifold
5" round to 6"
oval adapter
6" oval
pipe
5" round to 6"
oval adapter
5" Flex
to fireplace
© Travis Industries, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pb 36cf564 25k564 35k3615ho98900778

Table of Contents