Specifications Of Electrical Parts - Toshiba RAS-5M51U2ACVG-SG Service Manual

Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

No.
Parts name
1
Compressor
2
Outdoor fan motor
3
Reactor
4
Reactor
5
PMV coil
6
P.C. board (Main PCB)
7
P.C. board (Control PCB)
8
P.C. board (Fan motor connection)
9
Fuse (Mounted on P.C. board MCC-1571)
10
Fuse (Mounted on P.C. board MCC-1571)
11
Fuse (Mounted on P.C. board MCC-1571, WP-041)
12
Outdoor temp. sensor (TO sensor)
Discharge temp. sensor (TD sensor)
13
14
Temp. sensor at A room gas side (TGa-sensor)
15
Temp. sensor at B room gas side (TGb-sensor)
Temp. sensor at C room gas side (TGc-sensor)
16
Temp. sensor at D room gas side (TGd-sensor)
17
Temp. sensor at E room gas side (TGe-sensor)
18
19
Compressor thermo.
20
High-pressure SW
21
Terminal block (9P)
Model name
DX270A2T-20L
WDF-340-A100-1
CH-56-3Z-T
CH-76-VK
UKV-A039
MCC-1571
WP-041
MCC-1436P
CS-12AL
ACB-1UB177W
- 28 -
Rating
3 Phases (4-Poles) ; 2200 W
Output 100 W
5.8 mH, 18.5 A
9.9 mH, 1 A
DC 12 V
AC 220–240 V
DC 5V
AC 220–240V
AC 250V, 25 A
AC 250V, 10 A
AC 250V, 3.15 A
10 kΩ (25°C)
50 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
ON: 90°C, OFF: 125°C
OFF : 4.5MPa
AC 250 V, 20 A