Specifications - Toshiba RAS-5M51U2ACVG-SG Service Manual

Table of Contents

Advertisement

• Exposure of unit to water or other moisture before installation may result in an electrical short.
Do not store in a wet basement or expose to rain or water.
• Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify
the noise level of the unit or where noise or discharged air might disturb neighbors.
• To avoid personal injury, be careful when handling parts with sharp edges.
• Perform the specified installation work to guard against an earthquake.
If the air conditioner is not installed appropriately, accidents may occur due to the falling unit.
The indoor and outdoor units that can be used in combination are shown in the tables below.
Type
Outdoor unit
Cooling
RAS-5M51U2ACVG-SG
NOTES
A 1-room connection is not an option for the indoor units (you cannot connect only one indoor unit).
Be sure to connect indoor units in two or more.

2-1. Specifications

<Cooling Only Models>
RAS-5M51U2ACVG-SG
Unit models
Outdoor units
Indoor unit connecting of below performance spec.
Cooing capacity (rated)
Cooling capacity (range)
COP
Electrical
Power supply
characteristics
Power consumption
Running current
Power factor
Starting current
Outdoor unit operating noise
Sound pressure level
Sound power level
Characteristic
Compressor
and component parts spec.
Fan motor
Airflow rate
Refrigerant
Unit dimension
Net weight
Piping connection
Connecting method
Diameter
Maximum length (each unit)
Maximum length (total)
Maximum length (chargless)
Maximum height different
Wiring connection
Main power supply
Inter connection (each room)
Usable temperature range (outside)
Outdoor unit accessory
·
Performance specification with others Indoor unit combine are refer to combination table.
·
The specifications may be subject to change without notice for purpose of improvement.
2. SPECIFICATIONS
Table of models that can be used in combination
Combinations of indoor unit models that can be connected
Refer to page 11 to 16
Model
Type
Output
Model
Type
Output
Type
Weight charging
Height
Width
Depth
Unit A (liquid / gas side)
Unit B (liquid / gas side)
Unit C (liquid / gas side)
Unit D (liquid / gas side)
Unit E (liquid / gas side)
CAUTION
RAS-5M51U2ACVG-SG
RAS-M10U2KCVG-SG1 x5
(kW)
(kW)
-
220-240V., 50Hz.
(W)
(A)
(%)
(A)
(dBA)
(dBA)
-
-
Twin rotary with DC-inverter variable speed control
(W)
-
WDF-340-A100-1
-
DC motor with variable speed control circuit
(W)
3
(m
/h)
.
-
(kg.)
(mm.)
(mm.)
(mm.)
(kg.)
-
Flare connection
(mm.)
(mm.)
(mm.)
(mm.)
(mm.)
(mm.)
(mm.)
(mm.)
(mm.)
-
3wires included earth
-
4wires included earth
o
(
C)
.
-
- 10 -
8.30
3.70 - 11.5
4.90
1695
8.20/7.85/7.55
94
8.20
53
66
DX270A2T-20L
2200
100W
4460
R32
2.35
890
900
320
74
6.35 / 12.7
6.35 / 12.7
6.35 / 9.52
6.35 / 9.52
6.35 / 9.52
20
30
30
10
O
10 - 46
C
.
-