Troubleshooting Procedures (cont.)
Symptoms
7.
Chromatherapy
lights do not work.
8.
Remote control does
not work.
9.
Water does not
reach bath rim upon
filling.
1054216-2-A
Probable Causes
A. Damaged wiring harness.
B. Control does not work.
A. Batteries improperly
installed or dead.
B. Control does not work.
C. Remote control is not
programmed correctly.
D. Remote control does not
work.
E. Control switch does not
work.
A. No power to the unit.
B. Level probe wires loose.
C. Butterfly valves does not
work.
D. Control switch does not
work.
18
Recommended Action
a.
Check the wiring or
replace the control. Refer
to the installer/dealer.
b. Replace wiring harness.
Refer to the
installer/dealer.
a.
Replace the batteries.
b. Replace wiring harness.
Refer to the
installer/dealer.
c.
See homeowners guide or
service manual.
d. Replace the remote
control.
e.
Replace the control.
a.
Turn on the power.
b. Check/reconnect wires.
c.
Check wiring; replace
butterfly valves if
necessary.
d. Replace control.