Amplifier Units
Item
Model
Measurement period *1
Response time
Analog output *2
Judgement outputs
(HIGH/PASS/LOW: 3 outputs),
error output
Laser OFF input, zero reset input,
timing input, reset input,
bank input
Functions
Indications
Power supply voltage
Power consumption
Ambient temperature
Ambient humidity
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
*1. In the case of Omron's standard target object (white ceramic)
*2. Select current output (4 to 20 mA) and voltage output (±5V or 1 to 5V) by MENU mode.
*3. Calculating unit (ZX2-CAL) is necessary. Calculations are possible for up to two amplifier units. Mutual interference prevention is possible for
up to five amplifier units.
Calculating Unit
Item
Model
Applicable Amplifier Units ZX2-LDA11, ZX2-LDA41
12 mA max. (supplied from the Smart
Current consumption
Sensor Amplifier Unit)
Operating: 0 to +50°C, storage: -15 to
Ambient temperature
+70°C (with no icing or condensation)
Operating and storage: 35% to 85%
Ambient humidity
(with no condensation)
Connection method
Connector
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute
Vibration resistance
10 to 150 Hz, 0.7-mm double amplitude,
(destruction)
80 minutes, each in X,Y,and Z directions
Shock resistance
300 m/s
(destruction)
(up/down, left/right, forward/backward)
Materials
Case: ABS, Display: Methacrylic resin
Approx. 50g
Weight (packed state)
(Calculating Unit only: Approx. 15g)
Accessories
Instruction sheet
ZX2-LDA11
Min. 30 μs
60 μs, 120 μs, 240 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms, 12 ms, 20 ms, 36 ms, 66 ms, 128 ms, 250 ms,
500ms
4 to 20 mA, Max. load resistance: 300Ω/±5 VDC or 1 to 5 VDC, Output impedance: 100Ω
NPN open-collector outputs, 30 VDC, 50 mA max.
(residual voltage: 1 V max. for load current 10 mA
max., 2V max. for load current above 10 mA)
ON: Short-circuited with 0-V terminal or 1.2 V or less
OFF: Open (leakage current: 0.1 mA max.)
Smart tuning, scaling, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak hold,
self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/clamp switch,
(A-B) calculations *3, thickness calculation *3, mutual interference prevention *3,
laser deterioration detection, bank function (4 banks), differential function
Judgement indicators: HIGH (orange), PASS (green), LOW (orange), 11-segment main display (red),
11-segment sub-display (orange), laser ON (green), zero reset (green), enable (green), menu (green),
HIGH threshold (orange), LOW threshold (orange)
10 to 30 VDC, including 10% ripple (p-p)
3,000 mW max. (at 24 VDC: 125 mA max., at 12 VDC: 250 mA max.)
Operating: 0 to 50 °C, Storage: −15 to 70 °C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
1,000 VAC, 50/60 Hz for 1 min.
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions
2
300 m/s
3 times each in six directions (up/down, left/right, forward/backward)
IEC60529, IP40
Prewired (standard cable length: 2 m)
Approx. 200 g (main unit only: Approx. 135 g)
Case: PBT (polybutylene terephtahalate), Cover: Polycarbonate, Display: Methacrylic resin,
Button: Polyacetal, Cable: PVC
Instruction sheet
ZX2-CAL
2
3 times each in six directions
PNP open-collector outputs, 30 VDC, 50 mA max.
(residual voltage: 1 V max. for load current 10 mA
max., 2 V max. for load current above 10 mA)
ON: Supply voltage short-circuited or supply voltage
within -1.2 V
OFF: Open (leakage current: 0.1 mA max.)
ZX2-series Communications Interface Unit
Item
Model
10 to 30 V DC ±10% (including 10% ripple (p-p))
Power supply voltage
(Supplied from Sensor Amplifier.)
720 mW max. (at 24 V: 30 mA max., at 12 V: 60 mA max.)
Power consumption
(Not including Sensor Amplifier current consumption or
output current
Applicable Amplifier Units
ZX2-LDA@@ (Production after November 2013)
Sensor Amplifier Unit version: V1.330 or higher
Applicable Amplifier
(The Sensor Amplifier version is shown on the sub-digital
Unit versions
display when the power of the Sensor Amplifier is turned ON.)
Max. No. of Amplifier
5
Units
Port
RS-232C (9-pin, D-Sub connector)
Communications method Full duplex
Synchronization method Start/stop synchronization
Transmission code ASCII
Commu-
Baud rate
38,400 (at shipping)/9,600 bps switchable
nications
Data bit length 8 bits
functions
Parity check
None
Stop bit length 1 bit
Receiving CR or CR + LF is automatically recognized.
Data
delimiter
Sending CR + LF fixed
Power supply: green, Sensor communications: green, Sensor
Indicators
communications error: red, External terminal communications:
green, External terminal communications error: red
Protective circuits
Power supply reverse polarity protection
Operating: 0 to 50°C, storage: -15 to 60°C
Ambient temperature
(with no icing or condensation)
Operating and storage: 35% to 85%
Ambient humidity
(with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min,
Dielectric strength
Leakage current: 10 mA max.
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories
Instruction sheet, 2 clamps
ZX2
ZX2-LDA41
ZX2-SF11
6