Symptom
The product switches off during
operation. The LED flashes red.
C
Tables of gas settings
Applicability: Germany
OR Austria
OR Switzerland
Factory gas setting
Unit type for
Label on the data plate
Factory setting
Burner jets label
Gas flow
Gas family
Natural gas 2E/2H (G20)
Natural gas 2LL (G25)
Liquid gas 3P (G31)
Burner pressure
Gas family
Natural gas 2E/2H (G20)
Natural gas 2LL (G25)
Liquid gas 3P (G31)
D
Tables of gas settings
Applicability: Belgium
Factory gas setting
Unit type for
Label on the data plate
Factory setting
Burner jets label
0020271929_00 atmoMAG Installation and maintenance instructions
Possible cause
The flue gas guiding is restric-
ted, which causes overheating
(flue pipe is blocked).
Cable break or short circuit in
the cable on the safety cut-out
or flue gas sensor.
The safety cut-out or flue gas
sensor is defective.
Natural gases
DE: 2E
AT, CH: 2H
G20 – 2 kPa (20 mbar)
G20
11-4/1
14-4/1
085
085
Gas flow at nominal heat input in l/min
11-4/1
38.3
44.5
14.8
Burner pressure for nominal heat input
11-4/1
1.12 kPa (11.2 mbar)
0.97 kPa (9.7 mbar)
3.17 kPa (31.7 mbar)
Natural gases
2E+
G20/G25 – 2.0–2.5 kPa
(20–25 mbar)
G20
11-4/1
14-4/1
085
085
Measure
Check that the flue system has been installed correctly and
that there are no problems with the flue system.
Check how the cables are laid.
1.
Check the safety cut-out and flue gas sensor.
2.
Replace the defective component.
DE: 2LL
G25 – 2 kPa (20 mbar)
G25
11-4/1
14-4/1
100
102
14-4/1
48.7
56.0
18.8
14-4/1
1.38 kPa (13.8 mbar)
1.05 kPa (10.5 mbar)
3.45 kPa (34.5 mbar)
Liquefied petroleum gases
3P
G31 – 3.7 kPa (37 mbar)
G31
11-4/1
14-4/1
050
051
Appendix
Liquefied petroleum gases
DE, AT, CH: 3P
DE, AT: G31 – 5 kPa
(50 mbar)
CH: G31 – 3.7 kPa
(37 mbar)
G31
11-4/1
14-4/1
050
051
23